CRITICAL🇬🇧 English

CVE-2019-10919

CVSS 9.4v3.1pub. 2019-05-14upd. 2024-11-21

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

oryginał EN
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
  • Siemens Logo\!8 Bm

    HW
    Siemens
    wszystkie wersje
  • Siemens Logo\!8 Bm Firmware

    OS
    Siemens
    < 8.3
🔵
ZWERYFIKUJ U PRODUCENTA
Brak jednoznacznych danych o patchu. Sprawdź referencje od producenta.
Tagi
Auth Bypass
CWE
Referencje

Powiązane podatności

CVE-2022-36361CRITICAL9.8ten sam produkt

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6E...

CVE-2022-36360HIGH7.5ten sam produkt

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devi...

CVE-2022-36362HIGH7.5ten sam produkt

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED...

CVE-2019-10920HIGH7.5ten sam produkt

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data ...

CVE-2019-10921HIGH7.5ten sam produkt

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted s...