In Eclipse Milo versions 1.0.0 through 1.1.4, monitored-item quota accounting is not exception-safe: if item creation fails with an unchecked error, the server-global reservation is not restored. Deeply nested PubSub ExtensionObjects in a `CreateMonitoredItems` event filter can trigger a `StackOverflowError` during decoding, allowing an unauthenticated remote client to exhaust a finite global monitored-item quota and prevent all clients from creating new monitored items until restart. Existing monitored items and other server functions remain unaffected.
oryginał ENCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XEclipse Milo
APPEclipse1.0.0 – 1.1.5 (bez)