An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HSiemens Cp1604
HWSiemenswszystkie wersjeSiemens Cp1604 Firmware
OSSiemens< 2.8Siemens Cp1616
HWSiemenswszystkie wersjeSiemens Cp1616 Firmware
OSSiemens< 2.8Siemens Dk Standard Ethernet Controller
HWSiemenswszystkie wersjeSiemens Dk Standard Ethernet Controller Firmware
OSSiemens4.1.1< 4.1.1Siemens Ek Ertec 200
HWSiemenswszystkie wersjeSiemens Ek Ertec 200 Firmware
OSSiemens4.5.0< 4.5.0Siemens Ek Ertec 200p
HWSiemenswszystkie wersjeSiemens Ek Ertec 200p Firmware
OSSiemens< 4.5.0Siemens Scalance X 200irt
HWSiemenswszystkie wersjeSiemens Scalance X 200irt Firmware
OSSiemens< 5.2.1Siemens Simatic Et 200ecopn
HWSiemenswszystkie wersjeSiemens Simatic Et 200ecopn Firmware
OSSiemenswszystkie wersjeSiemens Simatic Et 200m
HWSiemenswszystkie wersjeSiemens Simatic Et 200m Firmware
OSSiemenswszystkie wersjeSiemens Simatic Et 200s
HWSiemenswszystkie wersjeSiemens Simatic Et 200s Firmware
OSSiemenswszystkie wersjeSiemens Simatic Pn\/pn Coupler 6es7158 3ad01 0xa0
HWSiemenswszystkie wersjeSiemens Simatic Pn\/pn Coupler 6es7158 3ad01 0xa0 Firmware
OSSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu
HWSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu 312 Ifm
HWSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu 312 Ifm Firmware
OSSiemens< 3.3.17Siemens Simatic S7 300 Cpu 313
HWSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu 313 Firmware
OSSiemens< 3.3.17Siemens Simatic S7 300 Cpu 314
HWSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu 314 Firmware
OSSiemens< 3.3.17Siemens Simatic S7 300 Cpu 314 Ifm
HWSiemenswszystkie wersjeSiemens Simatic S7 300 Cpu 314 Ifm Firmware
OSSiemens< 3.3.17Siemens Simatic S7 300 Cpu 315
HWSiemenswszystkie wersje
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
Tags
DoS
Related vulnerabilities
CVE-2021-31337CRITICAL9.8ten sam produkt
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require au...
CVE-2021-27388CRITICAL9.8ten sam produkt
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for rem...
CVE-2021-27384CRITICAL9.8ten sam produkt
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variant...
CVE-2020-15798CRITICAL9.8ten sam produkt
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 ...
CVE-2022-47374HIGH7.5ten sam produkt
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 ...