CVSS 7.5v3.1pub. 2019-08-13upd. 2024-11-21

A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.

CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
  • Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc2

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware

    OS
    Siemens
    < 20.8
  • Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc Firmware

    OS
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1211c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1211c Firmware

    OS
    Siemens
    < 4.4
  • Siemens Simatic S7 1200 Cpu 1212c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1212c Firmware

    OS
    Siemens
    < 4.4
  • Siemens Simatic S7 1200 Cpu 1214c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1214c Firmware

    OS
    Siemens
    < 4.4
  • Siemens Simatic S7 1200 Cpu 1215c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1215c Firmware

    OS
    Siemens
    < 4.4
  • Siemens Simatic S7 1200 Cpu 1217c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1200 Cpu 1217c Firmware

    OS
    Siemens
    < 4.4
  • Siemens Simatic S7 1500 Cpu 1511c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1500 Cpu 1511c Firmware

    OS
    Siemens
    < 2.8.1
  • Siemens Simatic S7 1500 Cpu 1512c

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1500 Cpu 1512c Firmware

    OS
    Siemens
    < 2.8.1
  • Siemens Simatic S7 1500 Cpu 1518

    HW
    Siemens
    wszystkie wersje
  • Siemens Simatic S7 1500 Cpu 1518 Firmware

    OS
    Siemens
    < 2.8.1
  • Siemens Simatic S7 1500 Software Controller

    APP
    Siemens
    < 20.8
  • Siemens Simatic S7 Plcsim Advanced

    APP
    Siemens
    < 3.0
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
CWE
References

Related vulnerabilities

CVE-2022-38465CRITICAL9.3ten sam produkt

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200...

CVE-2023-46156HIGH7.5ten sam produkt

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attack...

CVE-2023-28831HIGH8.7ten sam produkt

The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability tha...

CVE-2021-40365HIGH7.5ten sam produkt

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could all...

CVE-2021-42029HIGH7.8ten sam produkt

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Por...