A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:NSiemens Simatic Hmi Comfort Outdoor Panels
HWSiemensall versionsSiemens Simatic Hmi Comfort Outdoor Panels Firmware
OSSiemens< 15.1Siemens Simatic Hmi Comfort Panels
HWSiemensall versionsSiemens Simatic Hmi Comfort Panels Firmware
OSSiemens< 15.1Siemens Simatic Hmi Ktp Mobile Panels Ktp400f
HWSiemensall versionsSiemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
OSSiemens< 15.1Siemens Simatic Hmi Ktp Mobile Panels Ktp700
HWSiemensall versionsSiemens Simatic Hmi Ktp Mobile Panels Ktp700f
HWSiemensall versionsSiemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
OSSiemens< 15.1Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
OSSiemens< 15.1Siemens Simatic Hmi Ktp Mobile Panels Ktp900
HWSiemensall versionsSiemens Simatic Hmi Ktp Mobile Panels Ktp900f
HWSiemensall versionsSiemens Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
OSSiemens< 15.1Siemens Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
OSSiemens< 15.1Siemens Simatic Hmi Mp
HWSiemensall versionsSiemens Simatic Hmi Mp Firmware
OSSiemensall versionsSiemens Simatic Hmi Op
HWSiemensall versionsSiemens Simatic Hmi Op Firmware
OSSiemensall versionsSiemens Simatic Hmi Tp
HWSiemensall versionsSiemens Simatic Hmi Tp Firmware
OSSiemensall versionsSiemens Simatic Wincc Runtime
APPSiemens< 15.1Siemens Simatic Wincc \(tia Portal\)
APPSiemens< 15.1
Related vulnerabilities
Siemens SmartVNC — podatność out-of-bounds w obsłudze układu urządzenia (RCE)
Brak uwierzytelnienia w usłudze telnet paneli Siemens SIMATIC HMI
Siemens SIMATIC HMI — atak brute-force na Sm@rt Server (brak blokady prób logowania)
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 ...
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of ser...