A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.

🤖 AI Analysis
How it works

The vulnerability results from improper enforcement of user authentication at specific API endpoints when identity federation mechanism is configured. An attacker who knows the identity of a legitimate user can send specially crafted requests to these unprotected endpoints and bypass required authentication. A necessary condition for carrying out the attack is that identity federation is currently active or was previously used on the device, and the attacker possesses information about the identity of at least one legitimate user.

Impact

A successful attack allows an unauthenticated remote attacker to impersonate a legitimate system user, which may lead to unauthorized access to data, industrial device configuration, and potentially compromise the integrity and availability of the Industrial Edge environment.

Mitigation & patch

Software must be updated to versions that eliminate the vulnerability: Industrial Edge Device Kit V1.20 to V1.20.2-1 or later, V1.21 to V1.21.1-1 or later; Industrial Edge Own Device (IEOD) and Industrial Edge Virtual Device to V1.21.1-1-a or later; SCALANCE LPE9413 to V2.1 or later; SIMATIC IPC BX-39A, BX-59A, IPC127E, IPC227E, IPC427E, IPC847E to V3.0 or later. For versions V1.17, V1.18, and V1.19, no patched versions are indicated — consult with the manufacturer and review Siemens ProductCERT advisories: SSA-634640 and SSA-819629. As a temporary measure, consider disabling identity federation functionality where it is not essential.

Who is affected

Industrial Edge Device Kit (arm64 and x86-64) in versions V1.17, V1.18, V1.19 (all versions) and V1.20 (below V1.20.2-1) and V1.21 (below V1.21.1-1); Industrial Edge Own Device (IEOD) below V1.21.1-1-a; Industrial Edge Virtual Device below V1.21.1-1-a; SCALANCE LPE9413 (6GK5998-3GS01-2AC2) below V2.1; SIMATIC IPC BX-39A, BX-59A, IPC127E, IPC227E, IPC427E, IPC847E Industrial Edge Device — all versions below V3.0

Analysis generated by Claude AI (Anthropic) based on NVD data. Always verify with vendor.
CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
CWE
References