CVE-2025-30042

CVSS 9.0v4.0pub. 2026-03-02upd. 2026-03-09

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.

🤖 AI Analysis
How it works

Smart card authentication in the CGM CLININET system is performed locally on the client device, and access verification is based solely on the certificate number. In practice, the system does not verify either the actual presence of the smart card or the possession of the corresponding private key. This means that a person who knows another user's certificate number can impersonate them and gain access to the system without any additional authentication component.

Impact

An attacker possessing the certificate number of any user can gain full unauthorized access to the CGM CLININET system with that user's privileges, which in a medical environment poses a risk of disclosure, modification, or deletion of sensitive patient data as well as disruption of hospital system continuity.

Mitigation & patch

Patches available from the manufacturer should be applied in accordance with the references. Additionally, it is recommended to verify that the authentication process has been moved to the server side and includes cryptographic confirmation of private key possession (e.g., via a challenge-response mechanism), rather than merely checking the certificate number.

Who is affected

CGM CLININET system — versions indicated in the manufacturer's references

Analysis generated by Claude AI (Anthropic) based on NVD data. Always verify with vendor.
CVSS Vector
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
  • Cgm Clininet

    APP
    Cgm
    < 2025.ms2
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
CWE
References

Related vulnerabilities

CVE-2025-58402HIGH7.1same product

The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorizati...

CVE-2025-58405MEDIUM5.3same product

Aplikacja CGM CLININET nie implementuje żadnych mechanizmów zapobiegających atakom clickjacking — nie wykryto ...

CVE-2025-58406MEDIUM5.3same product

Aplikacja CGM CLININET odpowiada bez zasadniczych nagłówków bezpieczeństwa HTTP, narażając użytkowników na ata...