MEDIUM🇵🇱 Wersja polska

CVE-2026-63248

CVSS 6.9v4.0pub. 2026-08-04upd. 2026-08-05

In Eclipse Milo versions 0.6.0 through 1.1.4, OPC UA server diagnostics nodes do not enforce access authorization. An anonymous client can enable diagnostics over a None/None endpoint without a certificate; with a trusted client application certificate over SignAndEncrypt, it can read security diagnostics for other active sessions, exposing usernames, login history, authentication mechanisms, security modes and policies, and public client certificates.

CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
  • Eclipse Milo

    APP
    Eclipse
    0.6.0 – 1.1.5 (excl.)
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
CWE
References

Related vulnerabilities

CVE-2026-60007CRITICAL9.1PL ✓same product

Eclipse Milo: padding oracle w uwierzytelnianiu OPC-UA umożliwia odzyskanie hasła

CVE-2026-58080HIGH8.8PL ✓same product

Eclipse Milo: utrata RoleMapper przy kopiowaniu konfiguracji OPC UA

CVE-2026-62927HIGH8.7PL ✓same product

Eclipse Milo: ominięcie autoryzacji przez batch w usłudze Call

CVE-2026-63252HIGH8.7PL ✓same product

Eclipse Milo: wyczerpanie pamięci przez niekompletne chunki OPC UA

CVE-2026-61387MEDIUM6.9same product

In Eclipse Milo versions 1.0.0 through 1.1.4, monitored-item quota accounting is not exception-safe: if item c...